§ 431.446. Small electric motors energy conservation standards and their effective dates.
282 words·~1 min read·
/us/cfr/t10/s§ 431.446·A research copy — for the controlling text, always check the official state or federal source. Not legal advice.
(a)Each small electric motor manufactured (alone or as a component of another piece of non-covered equipment) after March 9, 2015, or in the case of a small electric motor which requires listing or certification by a nationally recognized safety testing laboratory, after March 9, 2017, shall have an average full load efficiency of not less than the following: Motor horsepower/standard kilowatt equivalent Average full load efficiency Polyphase Open motors (number of poles) 6 4 2 0.25/0.1867.569.565.6 0.33/0.2571.473.469.5 0.5/0.3775.378.273.4 0.75/0.5581.781.176.8 1/0.7582.583.577.0 1.5/1.183.886.584.0 2/1.5N/A86.585.5 3/2.2N/A86.985.5 Motor horsepower/standard kilowatt equivalent Average full load efficiency Capacitor-start capacitor-run and capacitor-start induction-run Open motors (number of poles) 6 4 2 0.25/0.1862.268.566.6 0.33/0.2566.672.470.5 0.5/0.3776.276.272.4 0.75/0.5580.281.876.2 1/0.7581.182.680.4 1.5/1.1N/A83.881.5 2/1.5N/A84.582.9 3/2.2N/AN/A84.1
(b)For purposes of determining the required minimum average full load efficiency of an electric motor that has a horsepower or kilowatt rating between two horsepower or two kilowatt ratings listed in any table of efficiency standards in paragraph
(a)of this section, each such motor shall be deemed to have a listed horsepower or kilowatt rating, determined as follows:
(1)A horsepower at or above the midpoint between the two consecutive horsepower ratings shall be rounded up to the higher of the two horsepower ratings;
(2)A horsepower below the midpoint between the two consecutive horsepower ratings shall be rounded down to the lower of the two horsepower ratings; or
(3)A kilowatt rating shall be directly converted from kilowatts to horsepower using the formula 1 kilowatt = (1/0.746) hp, without calculating beyond three significant decimal places, and the resulting horsepower shall be rounded in accordance with paragraphs (b)(1) or (b)(2) of this section, whichever applies. [75 FR 10947, Mar. 9, 2010; 75 FR 17036, Apr. 5, 2010]
Connections83 cite this
Cited by 83 sections · top 16
register
- Presidential DocumentsFinal rule
- NoticesNotice of petition and request for public comments
- NoticesRequest for information (RFI)
- Proposed RulesNotice of proposed rulemaking and request for comment
- Proposed RulesRequest for information
- NoticesNotice of proposed rulemaking
- NoticesFinal rule
- Rules and RegulationsFinal determination
- Proposed RulesRequest for information
- Rules and RegulationsFinal determination
- NoticesNotice of proposed rulemaking and announcement of public meeting
- NoticesNotice of proposed rulemaking and announcement of public meeting
- Proposed RulesNotification of proposed determination and request for comment
- NoticesNotification of proposed determination and request for comment
- Presidential DocumentsNotice of proposed rulemaking and announcement of public webinar
- Proposed RulesRequest for information
Citation graph
cites case law
§ 431.446
Small electric motors energy conservation standards and their effective dates.
Fed. Reg.×83
Cites 0Cited by 83 across 1 source